Model
SLU1500/12 tube
Collector tubes
SL-I-1500 (1.5 meter)
Number of tubes
12
U tube material
Copper
U tube
Diameter 8 mm
Thickness 1 mm
Max. Pressure (working)
0.6 MPa=6 bar (about 6 atmospheres), tested to 9 bar
Area, m2
Gross/"Aperature" 1.278 Absorber 0.858
Intercept efficiency (h0)
0.593 Aperature (0.883 Absorber, 0.616 European conversion for RETScreen Frta)
Heat Loss (a1)
FrUL=1.293 W/(m2K) (European format converted for RETScreen)
Net Weight
30 kg
Reflector
Flat Plate Diffuse, Aluminum
Inlet and Outlet Piping, in
1/2” (12 tube), stainless steel
Stagnation Temperature
220 degrees C, with reflector
Energy per year
525 kWh/m2
12 Tube Solar Panel Dimensions
12 Tube Solar Panel Dimensions.pdf